Smog season

Urban smog: how to protect indoor air

If smog enters your apartment, limit uncontrolled outdoor entry, avoid indoor sources and use suitable filtration. Time ventilation using actual outdoor conditions. Permanently closed windows are not a complete solution because a purifier does not remove CO₂.

Use measurements, not visibility alone

Check the update time and several-hour trend at nearby official monitors. Compare like units: AQI and µg/m³ are different. A distant station may not represent a road-facing courtyard. A home sensor helps assess the indoor trend but cannot replace outdoor monitoring.

Create one manageable room

Choose the room your household uses most. Close the window facing the source, check leakage and keep purifier airflow clear. Never obstruct mandatory ventilation or safety air supplies. Avoid candles and smoking and use extraction during cooking.

Calculate airflow for that room

A 25 m² room with a 2.7 m ceiling has a volume of 67.5 m³. Four theoretical treatments per hour require about 270 m³/h CADR. Four is an example calculation, not a health guarantee. Quiet-speed airflow is lower than maximum, and closed adjoining rooms need separate assessment.

Choose when to ventilate

When outdoor conditions improve, ventilate and then resume filtration. Watch temperature and stuffiness and use a separate CO₂ sensor if available. If safe ventilation remains impossible for a prolonged period, seek building advice; particle filtration cannot resolve accumulating gases and heat.

Particles are not the whole mixture

Smog may contain gases as well as particles. Lower PM2.5 does not establish removal of every component. Record window position, speed and readings so useful routines can be repeated. Do not use an intentional ozone-producing mode for occupied-room filtration.

Frequently asked questions

Is smog always visible?

No. Visibility and smell do not replace measurements.

Can I just close windows all day?

Temperature and ventilation still matter; particles and CO₂ require different measures.

Is advertised floor area enough?

No. Match CADR to the actual room volume and operating speed.

Sources and scope of the evidence

General principles were checked against these sources. Worked examples illustrate calculations and are not GL-K180 test results. Citing an organisation does not imply its endorsement of the model.